国产无遮挡又黄又湿又免费的视频_99riAV精品视频在线观看_久久天天看片免费_成人在线香蕉视频_99无码人妻一区二区三区免费

產品分類

Product category

技術文章 / article 您的位置:網站首頁 > 技術文章 > 電能管理系統在商業廣場的應用

電能管理系統在商業廣場的應用

發布時間: 2022-12-07  點擊次數: 647次

安科瑞 陳聰

 Application of Energy Management System in Commercial Plaza


摘要:介紹某國際商業廣場項目,采用智能電力儀表、采集配電現場的各種電參量、開關信號。系統采用現場就地組網的方式,組網后通過現場總線通訊并遠傳至后臺,通過Acrel-3000型電能管理系統實現樓層及配電房回路用電的實時監控和管理。

Abstract: Introduce an international commercial plaza project, which adopts smart power meters to collect various electrical parameters and switch signals at the distribution site. The system adopts the method of on-site networking. After networking, it communicates via fieldbus and transmits it to the background. The Acrel-3000 power management system realizes real-time monitoring and management of the power consumption of floors and power distribution rooms.

關鍵詞:智能電力儀表;Acrel-3000;電能管理系統;

Keywords: intelligent power meter; Acrel-3000; Energy management system;

0 概述 Overview

該項目位于某經濟開發區核心,區域內發展成熟,配套完善、交通便捷。本項目為現場各樓層配電間的用能改造?,F場757個配電出線回路安裝757臺多功能電表采集現場數據。

The project is located in the core of an economic development zone, with mature development, complete supporting facilities and convenient transportation. This project is the energy utilization transformation of the distribution rooms on each floor of the site. On-site 757 power distribution outgoing circuits were installed with 757 multi-function meters to collect field data.

1 需求分析 Demand Analysis

為保證生產管理用電負荷的統計與分析及對危險源實時監控。需要對項目現場的各配電箱等電氣設備進行電壓、電流、功率等參數進行實時在線監控。一旦監控點被監視參數異常,能夠及時檢測報警,有關人員采取必要的措施,避免安全事故的發生。自動抄表功能節省了人力物力,功率趨勢曲線功能能夠直觀的顯示各回路的工作狀態與時間,方便用戶找出非正常用電回路并且及時進行整改,建立電能多級計量體系提供用能分析依據。

本技術條件適用于該項目的回路進出線回路。供方產品應具有高安全性與可靠性、易于擴展、便于維修與維護。供方提供的產品應至少滿足本技術條件,但不僅于此,其技術性能應滿足對設備配電箱數據監控的要求。

To ensure the statistics and analysis of electricity load for production management and real-time monitoring of hazard sources. Real-time online monitoring of voltage, current, power and other parameters of electrical equipment such as distribution boxes on the project site is required. Once the monitoring point is monitored with abnormal parameters, it can detect and alarm in time, and relevant personnel can take necessary measures to avoid safety accidents. The automatic meter reading function saves manpower and material resources. The power trend curve function can intuitively display the working status and time of each circuit, which is convenient for users to find abnormal power circuits and make corrections in time, and establish a multi-level electrical energy measurement system to provide energy analysis basis .

This technical condition applies to the incoming and outgoing circuits of the project. The supplier's products should have high safety and reliability, easy to expand, easy to repair and maintain. The products provided by the supplier shall meet the technical requirements at least, but not only this, but the technical performance shall meet the requirements for data monitoring of the equipment distribution box.

1.1 數據采集 Data Collection

自動采集現場所有電量儀表的模擬量數據,自動采集現場開關狀態以及故障狀態等開關量數據。

支持實時采集、自動周期采集(定時采集)可配置周期(1分鐘~24小時)。

支持數據傳輸正確性檢驗,異常數據自動處理。

支持多線程處理機制,提高數據采集效率,能同時對多個設備進行數據采集。

數據實時顯示采用配電箱主接線圖直觀顯示模式,各回路開關斷合以及故障狀態直觀可見。

Automatically collect analog data of all power meters on site, and automatically collect on-site switching data such as on-site switch status and fault status.

Support real-time collection, automatic periodic collection (timing collection) configurable cycle (1 minute to 24 hours).

Support data transmission correctness inspection, automatic processing of abnormal data.

Support multi-threaded processing mechanism, improve the efficiency of data collection, and can collect data from multiple devices at the same time.

The real-time data display adopts the intuitive display mode of the main wiring diagram of the distribution box, and the disconnection and fault status of each circuit switch are intuitively visible.

1.2 數據分析與處理 Data Analysis And Processing

數據的綜合統計、分析需要實現以下功能:

各設備用電數據小時、日、月、年等時間段內的統計、計算。

各設備的用電負荷(有功、無功)大、小、平均值計算。

統計各分站及整體的用電量(有功、無功)。

Comprehensive statistics and analysis of data need to achieve the following functions:

Statistics and calculation of the electricity consumption data of each equipment within hours, days, months, years and other time periods.

Calculate the large, small and average value of the electrical load (active power, reactive power) of each device.

Count the power consumption (active power and reactive power) of each substation and the whole.

1.3 數據查詢與展示 Data Query And Display

要求能方便實現客戶端查詢和各級管理人員的查詢,查詢界面能適應各級管理人員的要求能夠支持靈活的條件組合查詢和對比分析,各類統計分析的數據可靈活采用報表等多種圖表方式直觀的展示功能。

數據展示功能按照不同用戶的不同的權限,分為操作層、管理層、決策層三層用能展示。

操作層具備用能分析、累計用量、實時監測、運行記錄及比例、對比、對標分析等功能。

管理層具備用能數據統計和分析、分類分項的對比、對標分析等功能。

決策層具備用能數據分析、數據刪除、數據庫導入/導出等功能。

It is required to facilitate the realization of client query and query of managers at all levels. The query interface can adapt to the requirements of managers at all levels. It can support flexible condition combination query and comparative analysis. Various types of statistical analysis data can be flexibly used in reports and other charts. Intuitive display function.

According to the different permissions of different users, the data display function is divided into three layers: operation layer, management layer, and decision-making layer.

The operation layer has functions such as energy consumption analysis, cumulative consumption, real-time monitoring, running records and ratios, comparison, and benchmarking analysis.

The management has functions such as statistics and analysis of energy consumption data, comparison of classification and sub-items, and benchmarking analysis.

The decision-making layer has functions such as energy data analysis, data deletion, and database import/export.

1.4 權限管理 Authority Management

要求對不同用戶賦予不同角色的權限,能授權到功能子菜單、具體檔案記錄、數據記錄等。

系統要求具備合理完善的用戶安全控制機制,能使應用環境中的信息資源得到保護,防止信息的丟失、失竊和破壞。

It is required to assign different roles to different users, and be able to authorize function sub-menus, specific file records, data records, etc.

The system requires a reasonable and complete user security control mechanism to protect the information resources in the application environment and prevent the loss, theft and destruction of information.

1.5 節能改造及效果評估 Energy-Saving Renovation And Effect Evaluation

要求為生產節能改造提供數據支撐,并能提供節能改造前后的效果評估。

It is required to provide data support for the energy-saving transformation of production, and provide the effect evaluation before and after the energy-saving transformation.

1.6 參數設置 Parameter Settings

可通過采集柜設置各回路互感器變比,各種電流電壓保護整定值。

故障判斷與報警具有故障自動判斷并采用聲光方式報警功能。報警類型包括開關故障,電壓、電流超限,現場采集模塊通訊故障,與監控系統通訊故障等。報警時間自動記入系統數據庫,方便用戶查詢,工作人員可隨時掌握變配電站實時運行狀態,發現變配電運行故障并作出相應處理,提高變配電的管理效率,提升電力系統安全性、可靠性。

The transformer ratio of each loop and the setting value of various current and voltage protection can be set through the acquisition cabinet.

Fault judgment and alarm have automatic fault judgment and use sound and light alarm function. Alarm types include switch failures, voltage and current overruns, communication failures of the field acquisition module, and communication failures with the monitoring system. The alarm time is automatically recorded in the system database, which is convenient for users to inquire. The staff can grasp the real-time operation status of the substation at any time, find the operation failure of the substation and distribution, and make corresponding treatments, improve the management efficiency of the substation and distribution, and enhance the safety of the power system. reliability.

2 系統方案 System Solutions

安科瑞Acrel-3000系統根據該項目的現場實際情況,整體網絡結構采用屏蔽雙絞線直接接至監控室的對應的數據采集器然后通過網線直接接至監控主機,保障了電能管理監控系統傳輸的穩定性與實時性。如下圖所示:站控管理層、網絡通訊層和現場設備層。

According to the actual situation of the project site, the Acrel-3000 system uses shielded twisted-pair cable to connect directly to the corresponding data collector in the monitoring room and then directly connects to the monitoring host through the network cable, ensuring the transmission of the power management monitoring system. The stability and real-time performance. As shown in the figure below: station control management layer, network communication layer and field device layer.

現場共計140只多功能儀表分為12條RS485總線接至配電房的監控工控機,實現總線上儀表與監控主機的數據連通。

A total of 140 multi-function instruments on site are divided into 12 RS485 buses connected to the monitoring industrial computer in the power distribution room to realize the data connection between the instruments on the bus and the monitoring host.

1)站控管理層 Station Control Management

站控管理層針對電力監控系統的管理人員,是人機交互的直接窗口。在該項目中主要指置于配電房的監控主機。

The station control management layer is the direct window of human-computer interaction for the management personnel of the power monitoring system. In this project, it mainly refers to the monitoring host placed in the power distribution room.

2)網絡通訊層 Network Communication Layer

 通訊層主要是由監控工控機的通訊串口、以太網設備及總線網絡組成。串口主要功能是監測現場智能儀表;以太網設備及總線網絡的主要功能是實現分站與主站之間的數據交互,使配電系統管理集中化、信息化、智能化,很大提高了配電系統的安全性、可靠性和穩定性,達到了無人值守的目的。

The communication layer is mainly composed of the communication serial port of the monitoring industrial computer, Ethernet equipment and bus network. The main function of the serial port is to monitor on-site intelligent instruments; the main function of the Ethernet equipment and the bus network is to realize the data interaction between the substation and the main station, so that the management of the distribution system is centralized, informatized, and intelligent, which greatly improves the distribution The safety, reliability and stability of the electrical system have achieved the goal of unattended operation.

3)現場設備層 Field Device Layer

現場設備層是數據采集終端,主要由智能儀表組成,智能儀表通過屏蔽雙絞線RS485接口,采用MODBUS通訊協議總線型連接接入通訊服務器,經通訊服務器到達該配電間監控主機進行組網,實現遠程控制。

The field device layer is the data acquisition terminal, which is mainly composed of smart meters. The smart meters are connected to the communication server through the shielded twisted pair RS485 interface and the MODBUS communication protocol bus connection. The communication server reaches the monitoring host of the power distribution room for networking. Realize remote control.

4) 智能儀表現場連接示意Smart Instrument Connection Diagram

現場儀表以手拉手方式通過屏蔽雙絞線(RVSP2*1.0)進行通訊連接,每根總線連接智能儀表數量在20只左右,不同種類的智能裝置連接在不同的總線上,然后將數據上傳至串口服務器,進而將數據上傳至當地監控終端。具體連接示意圖如下所示:

Field instruments are connected hand in hand through shielded twisted pair (RVSP2*1.0). The number of smart instruments connected to each bus is about 20. Different types of smart devices are connected to different buses, and then the data is uploaded to the serial port. The server then uploads the data to the local monitoring terminal. The specific connection diagram is as follows:

3 系統功能 System Functions

現場實時監控系統圖為主監控畫面,主要實時監測變電所所有回路的運行狀態,紅色代表合閘,綠色代表分閘。在系統圖中可以直觀的看到每路進線和出線的運行參數和狀態,可以看到變壓器出線側的所有常規電力參數,如:三相電壓、電流、有功功率、無功功率、功率因數、頻率、有功電度等。如下圖所示:

The on-site real-time monitoring system diagram is the main monitoring screen, which mainly monitors the operating status of all circuits in the substation in real time. Red represents closing and green represents opening. In the system diagram, you can intuitively see the operating parameters and status of each incoming and outgoing line, and you can see all the conventional power parameters on the outgoing side of the transformer, such as: three-phase voltage, current, active power, reactive power, and power factor , Frequency, active power, etc. As shown below:

系統一次圖 System diagram

遙信和遙測報警功能,主要完成對低壓各出線回路的開關運行狀態和負載進線監控,對開關變位和負載越限彈出報警界面指示具體的報警位置并聲音報警,提醒值班人員及時處理。負載越限值在相應權限下可自由設置。具備歷史查詢功能。

The remote signaling and remote measurement alarm function mainly completes the monitoring of the switch operation status of the low-voltage outlet circuits and the load incoming line. The pop-up alarm interface for switch displacement and load limit violations indicates the specific alarm location and sounds the alarm to remind the duty personnel to deal with it in time. The load limit can be set freely under the corresponding authority. With historical query function.

事件告警記錄功能,主要完成對查詢時間段內出現的報警信息事件記錄以及發生時間,為值班人員提供依據并且分析事故發生的原因。

The event alarm recording function mainly completes the recording of the alarm information and the occurrence time of the alarm information that occurred during the query time period, and provides the basis for the staff on duty and analyzes the cause of the accident.

參數抄表功能,主要對低壓各出線回路的電參數進線查詢。支持任意時刻電參數查詢,具備數據導出和報表打印等功能。該報表查詢一科大廈樓層配電箱進出線各低壓回路的電參數,主要包括:三相電流、有功功率和有功電度。該報表各回路名稱和數據庫關聯,方便用戶修改回路名稱。如下圖所示

Parameter meter reading function, mainly to query the electrical parameters of the low-voltage outgoing circuit. Supports electrical parameter query at any time, with functions such as data export and report printing. This report queries the electrical parameters of the low-voltage circuits of the incoming and outgoing lines of the distribution box on the floor of the Yike Building, mainly including: three-phase current, active power and active energy. The name of each circuit in this report is associated with the database, which is convenient for users to modify the name of the circuit. As shown below

電參數抄表Electric parameter reading

用電量報表功能,可選擇時間段進行查詢,支持任意時間段電度累計查詢,具備數據導出和報表打印等功能。為值班人員提供了準確可靠的電能報表。該報表各回路名稱和數據庫關聯,方便用戶修改回路名稱。如下圖所示,顯示辦公樓實驗樓配電回路的準確用電量,用戶可以直接打印報表,可以以EXCEL格式另存到其他位置。 如下圖所示:

The power consumption report function can select the time period for query, supports the cumulative query of the power consumption at any time period, and has the functions of data export and report printing. Provide accurate and reliable electric energy report for the staff on duty. The name of each circuit in this report is associated with the database, which is convenient for users to modify the name of the circuit. As shown in the figure below, it shows the accurate power consumption of the power distribution circuit in the laboratory building of the office building. Users can directly print the report and save it to other locations in EXCEL format. As shown below:

 

 

電能報表Energy report

系統通訊結構示意圖,主要顯示系統的組網結構,系統采用分層分布式結構,同時監測間隔層設備的通信狀態。紅色表示通訊正常,綠色表示通訊故障。下圖為變電所通訊狀態示意圖。

A schematic diagram of the system communication structure, which mainly shows the network structure of the system. The system adopts a hierarchical distributed structure and monitors the communication status of the bay layer equipment. Red indicates that the communication is normal, and green indicates that the communication is faulty. The figure below is a schematic diagram of the communication status of the substation.

通訊結構示意圖 Communication structure diagram 

負荷趨勢曲線界面中可直觀的查看回路的負荷運行情況。查看實時和歷史趨勢曲線,點擊畫面相應按鈕或菜單項可以完成相應功能的切換;幫助用戶進線趨勢分析和故障追憶,具備曲線打印功能。為分析整個系統的運行狀況提供了直觀而方便的軟件支持。

In the load trend curve interface, the load operation of the loop can be viewed intuitively. View real-time and historical trend curves, click the corresponding button or menu item on the screen to complete the switch of the corresponding function; help users to enter the line trend analysis and fault recall, with the curve printing function. Provides intuitive and convenient software support for analyzing the operating status of the entire system.

4 結束語 Summary

在當今配電設施的應用中,配電安全性至關重要,本文介紹的Acrel-3000電能管理系統在商業廣場項目的應用,可以實現對供配電回路用電的實時監控,不僅能顯示回路用電狀況,還具有網絡通訊功能,可以與串口服務器、計算機等組成電能管理系統。系統實現對采集數據的分析、處理,實時顯示配電房內各配電回路的運行狀態,對負載越限具有彈出報警對話框、語音提示,并生成各種電能報表、分析曲線、圖形等,便于電能的遠程抄表以及分析、研究,該系統運行安全、可靠、穩定,為商業廣場項目解決用電問題提供了安全可靠的依據,取得了較好的企業效益。

In the application of today’s power distribution facilities, power distribution safety is of the utmost importance. The application of the Acrel-3000 power management system introduced in this article in the commercial plaza project can realize real-time monitoring of the power consumption of the power supply and distribution circuit, not only can display the circuit The power consumption status also has the function of network communication, which can form an electric energy management system with serial server, computer, etc. The system realizes the analysis and processing of the collected data, real-time display of the operating status of each power distribution circuit in the power distribution room, pop-up alarm dialogs, voice prompts for load overruns, and generates various energy reports, analysis curves, graphics, etc., It is convenient for remote meter reading, analysis and research of electric energy. The system is safe, reliable and stable in operation. It provides a safe and reliable basis for the commercial plaza project to solve electricity problems, and has achieved good corporate benefits.

參考文獻 Bibliography

1.Technical requirements of the Ministry of Housing and Urban-Rural Development[2008] No. 114.

2.Solutions for enterprise micro-grid system





蘇公網安備 32028102001251號